previous
  • Guide to Paperless Drywall
    Guide to Paperless Drywall
  • Buyer's Guide to Decking
    Buyer's Guide to Decking
  • 10 Basement-Remodeling Tips and Techniques
    10 Basement-Remodeling Tips and Techniques
  • Roofing articles, videos, tools, and materials
    Roofing articles, videos, tools, and materials
  • Deck Design & Construction Showcase
    Deck Design & Construction Showcase
  • 2012 HOUSES Awards
    2012 HOUSES Awards
  • 12 Remodeling Secrets Revealed
    12 Remodeling Secrets Revealed
  • Meet the Fine Homebuilding Project House!
    Meet the Fine Homebuilding Project House!
  • Complete Kitchen and Bath Guide
    Complete Kitchen and Bath Guide
  • 9 Design Ideas & Tips for Concrete Countertops
    9 Design Ideas & Tips for Concrete Countertops
  • Outdoor Kitchen Design Inspiration
    Outdoor Kitchen Design Inspiration
  • 7 Solutions for Kitchen Layout and Design
    7 Solutions for Kitchen Layout and Design
  • The Inspector Game: Decking Dos and Don'ts
    The Inspector Game: Decking Dos and Don'ts
  • Fine Homebuilding: The Digital Issues
    Fine Homebuilding: The Digital Issues
  • 7 Small Bathroom Floorplan Layouts
    7 Small Bathroom Floorplan Layouts
  • Energy-Smart Details
    Energy-Smart Details
  • How it Works
    How it Works
  • 15 Coffered Ceiling Design Ideas and Tips
    15 Coffered Ceiling Design Ideas and Tips
  • 13 Door Design and Installation Tips
    13 Door Design and Installation Tips
  • Painting Ideas, Tips, and Techniques for a Professional Finish
    Painting Ideas, Tips, and Techniques for a Professional Finish
next

ASHRE Ventilation Standard is too low

Recent research on residential ventilation presented at 2007’s American Society of Heating, Refrigerating, and Air-Conditioning Engineers conference is consistent with past research and current practice in Europe. Why is this news? Because it’s inconsistent with ASHRAE Standard 62.2: the Residential Ventilation Standard for the United States.

Research titled “Window Usage, Ventilation, and Formaldehyde Concentrations in New California Homes” (Offerman et. al.) measured formaldehyde levels in 100 recently built California homes. Offerman found that 0.5 air changes per hour (ACH) were necessary to dilute formaldehyde from building materials to an acceptable level. An ACH means that the volume of air in a house is completely replaced in an hour.

While these findings are consistent with research published in 2004 (Sherman and Hodgeson), they’re also about three times higher than the ASHRAE 62.2 rate. This means that the standard rate can’t adequately control formaldehyde levels in new homes.

From Fine Homebuilding194 , pp. 20 March 5, 2008