How to Use Spray Foam to Meet New Energy Codes in Warm Climates - Fine Homebuilding
previous
  • Shorten a Prehung Door
    Shorten a Prehung Door
  • All about Roofing
    All about Roofing
  • Tips & Techniques for Painting
    Tips & Techniques for Painting
  • Video: Build a curved step
    Video: Build a curved step
  • Remodeling in Action
    Remodeling in Action
  • 7 Smart Kitchen Solutions
    7 Smart Kitchen Solutions
  • 7 Small Bathroom Layouts
    7 Small Bathroom Layouts
  • The Hobbit House and More
    The Hobbit House and More
  • How to Install Housewrap Solo
    How to Install Housewrap Solo
  • Energy-Smart Details
    Energy-Smart Details
  • Play the Inspector Game!
    Play the Inspector Game!
  • Buyer's Guide to Insulation
    Buyer's Guide to Insulation
  • Basement Remodeling Tips
    Basement Remodeling Tips
  • The Passive House Build
    The Passive House Build
  • 12 Remodeling Secrets
    12 Remodeling Secrets
  • Read FHB on Your iPad
    Read FHB on Your iPad
  • 7 Trim Carpentry Secrets
    7 Trim Carpentry Secrets
  • Clever daily tip in your inbox
    Clever daily tip in your inbox
  • Magazine Departments
    Magazine Departments
  • 9 Concrete Countertops Ideas
    9 Concrete Countertops Ideas
  • Master Carpenter Videos
    Master Carpenter Videos
  • Deck Design & Construction
    Deck Design & Construction
  • Electrical Articles & Videos
    Electrical Articles & Videos
next


How to Use Spray Foam to Meet New Energy Codes in Warm Climates

comments (0) November 28th, 2013 in Blogs
Matt Risinger Matt Risinger, Blogger

Video Length: 4:18
Produced by: Matt Risinger


Building codes change on a three year cycle and we just had an update from the 2009 codes to the new 2012 International Residential Code (IRC) and the new 2012 International Energy Conservation Code (IECC). Austin TX adopted the 2012 IRC this month so all new houses starting now (Sept 2013) will be under the 2012 codes. Here's a link to the Austin Adopted ordinance to see the fine details.
I must admit that I don't own a copy of the building codes anymore. When I worked for a Production Builder 20 years ago having a copy of the Building Codes was a big deal mainly because we were always building at the minimums. Nowadays, I rarely need to refer to "code" and if I am looking something up it's usually handrail/guardrail related. (Remember that code is the worst legal house you can build)
Anyhow, the point of today's post is how the new insulation codes affect a house using spray foam. For a general overview of the IECC code change see this great article by Martin Holladay on Green Building Advisor. Also, remember if you are reading this blog from anywhere besides Austin you'll need to look up your climate zone. See this website for your zone lookup. (FYI, Austin TX is in Climate Zone 2)

Texas Climate Zone Map. Red is Zone 2, Orange is Zone 3, Yellow 4


CEILING INSULATION:
Ceilings have gone from R-30 to R-38 but that requirement is based upon fiberglass insulation on a flat drywall ceiling and a "hot" attic above. With a conditioned attic and spray foam under the roof deck the code has changed from R-21 to R-25. With open cell foam (approx R-3.8/inch) we used to use 5.5" inside the roof line to make code. (I'm also a big believer in using 2" of rigid foam sheets on the roof deck, see this video for my technique). Now to make the R-25 requirement you will need 7" of open cell spray foam. My new Risinger Homes standard is 8 inches of open cell at the roof line for R-30 insulation.

Spraying 8" of Open Cell Foam to the Roof Deck in a Risinger Home

WALL INSULATION:
Walls have gone from R-13 to R-15 OR R-13+2. The +2 is referring to exterior rigid foam that can be added to a standard 2x4 wall with R-13 insulation. This means that typical fiberglass batts in a 2x4 wall don't meet code anymore (finally), you'll need a total fill BIBS or Spray Foam to make the R-15 requirement in a 2x4 wall. My preference has long been to use a total fill insulation and open cell spray foam is tough to beat. It totally fills the stud cavity and it does a good job of air sealing inside that stud bay. Here are some photos of a Risinger Home under construction in Barton Creek my crew just insulated this week. We used 8" of foam in the roofline, and 5.5" in the Advanced Framed Walls.

I consider a conditioned attic a "Must" for the hot/humid south. All my ducts are inside the envelope.

 

Open cell foam does a nice job of thoroughly insulating this house. 

 

 

 

2x6 - 24" OC Stud walls are my preference for R-21 with 5.5" of foam

 

Advanced Framing: 2 Stud or CA Corner allows foam all the way to the edge. 

 

Looking up at a R-10 Insulated Header using 2 layers of 3/4" R-5 rigid foam. 

Best,
Matt Risinger

Risinger Homes is a custom builder and whole house remodeling contractor that specializes in Architect driven and fine craftsmanship work. We utilize an in-house carpentry staff and the latest building science research to build dramatically more efficient, healthy and durable homes. Follow me on Twitter @MattRisinger , or check out my video blog on YouTube.