How to Insulate Concrete Foundation Walls From the Inside Out - Fine Homebuilding
previous
  • Deck Design & Construction
    Deck Design & Construction
  • Tips & Techniques for Painting
    Tips & Techniques for Painting
  • Energy-Smart Details
    Energy-Smart Details
  • Basement Remodeling Tips
    Basement Remodeling Tips
  • Master Carpenter Videos
    Master Carpenter Videos
  • Gallery: Custom Flooring
    Gallery: Custom Flooring
  • Video Series: Install a Rock-Solid Tile Floor
    Video Series: Install a Rock-Solid Tile Floor
  • 7 Small Bathroom Layouts
    7 Small Bathroom Layouts
  • 7 Trim Carpentry Secrets
    7 Trim Carpentry Secrets
  • Solid Deck-Framing Advice
    Solid Deck-Framing Advice
  • All about Roofing
    All about Roofing
  • Read FHB on Your iPad
    Read FHB on Your iPad
  • 7 Smart Kitchen Solutions
    7 Smart Kitchen Solutions
  • Remodeling in Action
    Remodeling in Action
  • Video: Build a curved step
    Video: Build a curved step
  • Video: Install a Fence
    Video: Install a Fence
  • 12 Remodeling Secrets
    12 Remodeling Secrets
  • Clever daily tip in your inbox
    Clever daily tip in your inbox
  • Magazine Departments
    Magazine Departments
  • 9 Concrete Countertops Ideas
    9 Concrete Countertops Ideas
next

Editor's Notepad

Editor's Notepad


How to Insulate Concrete Foundation Walls From the Inside Out

comments (1) September 23rd, 2011 in Blogs
ScottG Scott Gibson, contributing writer


A builder planning a high-efficiency spec house wants to insulate the foundation walls, and is considering a type of panel that incorporates an inner layer of rigid foam insulation and two outer layers of concrete. Will it work?


Related articles from GBA

Green Basics: Insulated concrete forms

Should Insulated Concrete Forms be Air-Sealed?

Code Green: Mass Walls Increase Insulation Value

How to Finish Exterior Foundation Insulation


Peter Fusaro likes what he hears. The concrete protects the foam from damage, making this approach more appealing than leaving foam exposed on the exterior. He understands that 2 in. of extruded polystyrene insulation will give the wall an R-value of more than 19. That's the premise he takes to the Q&A forum at GreenBuildingAdvisor, and that's the subject of this week's Q&A Spotlight.

To GBA senior editor Martin Holladay, what Fusaro is describing sounds like the Thermomass Building Insulation System, which does claim an R-value of 19.27 for the 10-in. thick panel.

But as Holladay points out, the foam insulation only adds up to R-10. Don't mix up the effects of thermal mass with R-value, he warns.

Another concrete-and-foam option is insulating concrete forms. But in both cases, there's some question on what benefit, if any, Fusaro will reap from the thermal mass of the concrete. At least one reader thinks the effect will be minimal.

Read the whole article at Green Building Advisor.

 



posted in: Blogs

Comments (1)

Marty10fingers Marty10fingers writes: Have seen many poor insulation jobs and few moving to better practices. Doing some google I found a U. of Waterloo study helpful when considering retro fitting basement insulation and moisture issues.