What’s the Building Code for Housewrap Installation?

Code? What code? Well the IRC is pretty straight-forward: Prescriptive code measures + Manufacturers' Installation Instructions.

By Mike Guertin
Article Image
Housewrap Wrong - Often the building code for water-resistive barrier installation isn;t followed. Disasterous results

It’s common in my area to see housewrap installed improperly. Most city and town building inspectors only make four building inspections during the building process: (1) Footings/foundation before placing concrete, (2) Rough framing, after the utilities are roughed in, (3) Insulation / fireblocking / draftstopping, and (4) Final. Friends of mine in parts of Canada tell me that they are required to get a WRB/Window/Door installation inspection done. If we had that here, housewrap installation quality would probably rise significantly.

“It’s just housewrap. Who cares anyway? My siding doesn’t leak.”

Small siding leak + improper lap in housewrap = rot and pest infestation after only 10 years.

Siding jobs do leak so when the water-resistive barrier leaks, water can get into the wall and lead to mold and rot. Often the leak can go on for many years inside the wall before anyone notices.   And by the time it is discovered the damage can be extensive.

 

 

 

 

 

 

 

 

Small tears around hammer tacker staples let water leak behind the housewrap where the sheathing deteriorated after only 4 years.

It’s all outlined in the code

Though many builders think of the IRC as a low bar / bare minimum, when it comes to WRB installation the code is actually ‘best practice.’ It’s all in section R703 – Exterior Covering of the 2018 IRC.

R703.1.1 “The exterior wall envelope shall be designed and constructed in a manner that prevents the accumulation of water within the wall assembly by providing a water-resistant barrier behind the exterior cladding … and a means of draining to the exterior water that penetrates the exterior cladding.”

R703.2 Water-resistive barrier

This section gives us two options for materials: #15 lb tar paper meeting ASTM D226 requirements OR “other approved water-resistive barrier” (Meaning: approved by the local building official.) The manufacturers of plastic housewraps and other WRB materials generally obtain an ICC Evaluation Service Report that code officials rely on when determining whether to accept an alternative material to #15 tar paper or not. Though I’ve never heard of a local code official denying approval of a housewrap but it is within his authority.

 

On the installation side, when tar paper is used it must be “free from holes and breaks,” “applied horizontally,” with laps “not less than 2 inches.”   Vertical and other joints must be lapped 6 in. Fastening requirements for the WRB are not mentioned in the IRC. Figuring that tarpaper installation must be “free from holes and breaks,” it’s important to consider the effect of common installation practices like fine wire hammer-tacker staplers. Often the contact rim on a stapler rips a small hole each time the tacker is whacked. Another problem with fine wire staples is they frequently pull-through the WRB on windy days leaving holes that often don’t get patched.

And there are other WRB installation requirements that often gets overlooked “The No. 15 asphalt felt or other approved water-resistive barrier material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1”

Reverse overlaps, head flap folded into the rough opening, insufficient vertical laps, gaps, tears and staple tearouts are some of the common installation deficiencies. The manufacturers’ installation instructions must be followed in order to comply with the IRC requirements.

What about housewrap installation?

When “Other approved materials… are used as a WRB they shall be installed in accordance with the water-resistive barrier manufacturer’s installation instructions.” There it is — the manufacturer’s installation instructions are referenced in the code and are enforceable by the local official.

Housewrap manufacturers list their installation requirements in the instructions.   I read through several major housewrap manufacturer installation instructions and most have minimum horizontal overlaps of 4 in. or 6 in. and minimum vertical overlaps of 6 in. to 12 in. Most also require or recommend 1 in. plastic or metal cap fasteners. The caps protect the housewrap from damage during installation and spread the surface area of the fastener over a broader area of the WRB so the fastener is less likely to tear through.   The fastener spacing patterns vary widely between manufacturers. Some call for fasteners spaced as wide as 32 in. on center vertically and horizontally, others are as close as 12 in. oc in some circumstances.

Sign up for eletters today and get the latest how-to from Fine Homebuilding, plus special offers.

Sign Up

Get home building tips, offers, and expert advice in your inbox

×
X
X

New Feature

Fine Homebuilding Forums

Ask questions, offer advice, and share your work

View Comments

  1. bdrfab | Apr 30, 2018 03:33pm | #1

    In my part of Michigan we have WRB inspections, typically after window installation and before siding. This also means that they have not allowed one manufactures tape or flashing tape on anothers housewrap. For instance, Protecto wrap flashing tape on Tyvek. The reason for this is the housewrap manufacterers instructions call out their own product, not their competitors. The other wrinkle is that when using ZIP sheathing, very few manufactures include instructions for installation on that type of sheathing. I was able to get around it on that particular project by printing instructions off the window manufacturers website and taping them to each window. It's getting down right ridiculous sometimes.

    1. User avater
      Mike_Guertin | May 01, 2018 10:52pm | #2

      BFRFAB It does sound over the top on the inspection side - especially not permitting cross-use of products between different brands.

  2. DappledLight | Mar 14, 2019 01:28pm | #3

    When was the WRB requirement introduced? We purchased a home built about 12 years and during a remodel was shocked to discover there was no WRB and no window flashing. Aside from not following basic best practice for the era I was equally surprised the building inspector approved it. I went back to check the IRC requirements and it seemed to me WRB was a recent addition hence at the time of construction it was probably compliant (but poor practice), but I'm not a code expert, just a homeowner who was quite distressed. When did WRB become a requirement?

    1. User avater
      Mike_Guertin | Mar 15, 2019 12:58pm | #5

      I had to look back through several versions of the IRC to see when Water-Resistive Barrier (WRB) became required. There was a big change in table R703.4 between the 2003 version and the 2006 version that governed (along with a couple other sections) which siding materials must have a WRB.

      For homes built under the 2003 IRC most siding did not require a WRB. Homes built under the 2006 IRC and later versions, most siding is requires a WRB.

      In the 2015 IRC the column in table R703.4 was eliminated and most of the exceptions to the required WRB in section (R703.2) describing Water-resistive Barrier were eliminated. The only remaining exception where a WRB is not required is in detached accessory buildings (think garage or shed).

      What we think of as a modern window flashing system incorporating a sill pan and flashing applied to the sides and head of windows and doors was not specifically prescribed until the 2012 IRC. The 2012 IRC and subsequent versions require installation follow the window or door manufacturer's flashing instructions or the flashing manufacturer's instructions. Prior to that window and door flashings were required but the details of what would comply were vague or nonexistent.

      Local code officials can only enforce what their code jurisdiction (state, county, city/town) permits them to. In some areas the local official is allowed to enforce standards that go above and beyond what is prescribed in the adopted building code. In other areas code officials can only enforce what the adopted building code requires and nothing exceeding that. Sometimes there is room for interpretation in the code but usually the code is pretty clear.

      It is likely that the model IRC code in force at the time your house was built 12 years ago was the 2000 or 2003 version. Many jurisdictions don't adopt a new model code for several years after it has been published. So it could be that the local building official enforced the code properly; which, depending on your siding, didn't require a WRB or special flashing around the windows and doors. The 2000 and 2003 versions of the IRC permitted 'self-flashing' windows with 1-1/8 in. wide flanges. No WRB, no sealant, no additional flashing - just the window nailed to the framing or wall sheathing met the code.

      While we wouldn't consider your 12 year old house built to the old standards "code compliant" today it is viewed as through the lens of the code at the time it was built. Each new IRC version includes a section for Existing Structures "The legal occupancy of any structure existing on the date of adoption of this code shall be permitted to continue without change". With a couple of exceptions for heath and safety.

  3. user-6904308 | Mar 15, 2019 08:48am | #4

    FHB posted an excellent article on waterproofing with WRB around windows that seemed to go beyond what this covers. https://www.finehomebuilding.com/2008/07/03/installing-and-flashing-windows-correctly

  4. User avater
    Steffen_Werner | Mar 15, 2019 02:24pm | #6

    We don't have a required inspection here in Seattle however most of the A/E I work with require independent inspections for items such as this.

  5. user-6778127 | Apr 12, 2019 07:44pm | #7

    If a house passes inspection when it shouldn't have because the construction didn't meed the code requirements of the time, who is responsible?

    I haven't had a house built or had a remodel of an existing house, but when I do in the future, can I expect that there will be a warranty in the contract with the contractor that the construction is built to or exceeding minimal code standards, regardless of whether an inspector "signed off" on it? I have read enough to know that bad things can happen when best-practices aren't followed, but don't know nearly enough to recognize when shortcuts are taken. Do I have to rely on a building inspector to make sure that I get what I paid for?

Log in or create an account to post a comment.

Sign up Log in

Become a member and get full access to FineHomebuilding.com

More Job Site Diaries

View All
  • Shower niche

    Interior Finishes for a Cabin in the Woods

  • Cabin exterior

    Cladding Details That Last

  • Waterproofing system

    Shower Waterproofing

  • Slab Tile

    Finishing Touches for a Porcelain-Slab Shower

View All

Up Next

Featured Story

Fine Homebuilding Issue 297

Fine Homebuilding – February/March 2021, Issue #297

Featuring: Battery-Powered Cordless Framing Nailers; Successful Floors With Trusses; Sidewall Shingles With a Flare; and High-Performance Raft Slab

Featured Video

A Modern California Home Wrapped in Rockwool Insulation for Energy Efficiency and Fire Resistance

The designer and builder of the 2018 Fine Homebuilding House detail why they chose mineral-wool batts and high-density boards for all of their insulation needs.

Related Stories

  • Podcast 320: PRO TALK With Adam Feldman, Pt. 2

  • Podcast 319: Building in a Flood Zone, Who Pays for Warranty Work, and Converting Attics to Living Space

  • Fine Homebuilding Flashback: 1981, The Magazine's First Year

  • Podcast 318: PRO TALK With Adam Feldman, Pt. 1

Discussion Forum

Recent Posts and Replies

  • |
  • |
  • |
  • |
  • |
  • |
View More Create Post

Highlights

  • Fine Homebuilding All Access
  • Fine Homebuilding Podcast
  • Tool Tech

    Plus, get an extra 20% off with code GIFT20

  • "I have learned so much thanks to the searchable articles on the FHB website. I can confidently say that I expect to be a life-long subscriber." - M.K.

    Get home building tips, offers, and expert advice in your inbox

    Sign Up See all newsletters

Video

View All
  • Exterior PVC Trim: Windows and Doors

  • how to install PVC blocking for plumbing and electric fixtures

    Exterior PVC Trim: Wire and Pipe Penetrations

  • how to install PVC corner boards

    Exterior PVC Trim: Corners, Inside and Out

  • how to install PVC water table trim

    Exterior PVC Trim: Water Table and Cap

View All

Water and Moisture Control

View All
  • make a copper pipe flashing boot

    Make a Copper Flashing Boot

  • Installing ZIP System Sheathing: Penetrations

    Installing ZIP System Sheathing: Sealing Penetrations

  • Installing ZIP System Sheathing: Sheathing to Foundation Connection

    Installing ZIP System Sheathing: Sheathing-to-Foundation Connection

  • Installing ZIP System Sheathing: Taping Seams and Corners

    Installing ZIP System Sheathing: Taping Seams and Corners

View All

BOOKS, DVDs, & MERCH

Shop the Store
  • Fine Homebuilding Magazine Slipcase

    Buy Now
  • Musings of an Energy Nerd

    Buy Now
  • Code Check Building 4th Edition

    Buy Now
  • 2020 Fine Homebuilding Archive

    Buy Now
  • Shop the Store

Fine Homebuilding Magazine

  • Issue 297 - Feb/Mar 2021

    • Foundations for Success
    • Staircase Renovation
    • Ditch the Hose
  • Issue 296 - Dec 2020/Jan 2021

    • Insulating Glass Keeps Getting Better
    • Simple Way to Make Old Walls Straight and Plumb
    • Making Sense of Minisplits
  • Issue 295 - Kitchens & Baths

    • Condo Kitchen Reimagined
    • Row-House Remodel
    • Rise of the IAQ Monitor
  • Issue 294 - Oct/Nov 2020

    • Schoolhouse Reimagined
    • Tool Test: Folding Sawhorses
    • A Better Way to Build Tall Walls
  • Issue 293 - Aug/Sept 2020

    • A Practical Guide to Fall Protection
    • Installing Frameless Cabinets
    • Make Any Tablesaw Safer

Fine Homebuilding

Follow

Newsletter

Get home building tips, offers, and expert advice in your inbox

Sign Up See all newsletters

Membership & Magazine

  • Online Archive
  • Start Free Trial
  • Magazine Subscription
  • Magazine Renewal
  • Gift a Subscription
  • Customer Support
  • Manage Preferences

Taunton Network

  • Green Building Advisor
  • Fine Woodworking
  • Fine Gardening
  • Threads
  • About
  • Contact
  • Advertise
  • Privacy Policy
  • Careers
  • Copyright
  • Terms of Use
  • Accessibility
  • CA Privacy Rights

© 2021 The Taunton Press, Inc. All rights reserved.

    Main Menu

  • How-To
  • Design
  • Tools & Materials
  • Video
  • Blogs
  • Forum
  • Reader Projects
  • Magazine
  • Members
  • FHB House
  • Podcasts

  • FHB Podcast
  • ProTalk
  • Account

  • Log In
  • Join

    Podcasts

  • FHB Podcast
  • ProTalk
  • Popular Topics

  • Kitchens
  • Business
  • Bedrooms
  • Roofs
  • Architecture and Design
  • Green Building
  • Decks
  • Framing
  • Safety
  • Remodeling
  • Bathrooms
  • Windows
  • Tilework
  • Ceilings
  • HVAC

    Magazine

  • Current Issue
  • Past Issues
  • Magazine Index
  • Subscribe
  • Online Archive
  • Author Guidelines

    All Access

  • Member Home
  • Start Free Trial
  • Gift Membership

    Shop the Store

  • Books
  • DVDs
  • Taunton Workshops

    More

  • FHB Ambassadors
  • Reader Projects
  • Podcast
  • Customer Support

    Account

  • Log In
  • Join

Newsletter

Get home building tips, offers, and expert advice in your inbox

Sign Up See all newsletters

Follow

Join All Access

Become a member and get instant access to thousands of videos, how-tos, tool reviews, and design features.

Start Your Free Trial

Subscribe

FHB Magazine

Start your subscription today and save up to 52%

Subscribe

We hope you’ve enjoyed your free articles. To keep reading, become a member today.

Get complete site access to expert advice, how-to videos, Code Check, and more, plus the print magazine.

Start your FREE trial

Already a member? Log in